Method 8A (SO3) Controlled Condensate Sampling System – NCASI
Method 8A – NCASI is the determination of sulfuric acid vapor or mist, and sulfur dioxide SO3 emissions from kraft recovery furnaces. The ESC Controlled condensate system utilizes a high temperature oven to house a thimble filter holder followed by a heated coil condenser to achieve separation of sulfuric acid vapor or mist (including sulfur trioxide) and sulfur dioxide. (click on image to enlarge)
6' Quartz Heated Probe Liner
Heated Filter Box (up to 500°)
Single Station Digital Temperature Controller
Quartz Thimble Holder
13” Condenser
6” Inconnel Thermocouple Assembly
15 ft.Jumper Cable
Uses 30mm x 100mm Quartz Thimble Media
System Components
Qty. | Part # | Description |
1 | CCS-PRA-Q06 | 6 foot effective length quartz probe with heated liner |
1 | PRL-Q06 | 6 foot effective length quartz probe liner with ball joint and O-ring |
1 | CCS-HB | Heated filter box (up to 500°) |
1 | CCS-WRS | Heated water recirculation system |
1 | M5-DC-1 | Single station digital temperature controller |
1 | GP-CCS-101 | Quartz thimble holder with a # 28 in and out (2 recommended) |
1 | GP-CCS-102-NF | 13” Condenser with a #28 in and out (no frit) (2 recommended) |
1 | GP-CCS-103 | Pyrex “T” adapter 3/8” to ¼” (2 recommended) |
1 | PPIT-Y-06 | 6” Inconel thermocouple assembly |
1 | CCS-P4T3-15 | 15 ft. jumper cable with a 4 pin Amphenol and three thermocouples |
1 | PRI-T-Q30100 | Quartz Thimble style filter, box of 25 (30mm x100mm) |
All above parts sold separately